Industrial Machinery Agency
Industrial Machinery Agency


Diesel Gensets

Diesel Gensets

We offer a wide range of diesel gensets used for producing required electricity for captive consumption. These 1500 RPM diesel gensets are manufactured in various KVA ratings and specifications to satisfy the client''s different requirements. 

       The generating sets are manufactured by combining IMA 1500 RPM (Peter-type) Water-cooled/Air -cooled diesel engine with rasistive type or inductive type, Alternator of reputed brand.  

        

  • Available in single phase & three phase versions from 2.2KVA to 35 KVA.
  • Welding Gentsets are available from 2 to 4 KVA (1-phase).
  • Belt-driven (Lister-type)slow speed engine driven Generators ar also available from 3.5 KVA to 12 KVA.
  • Silent type and open type DG sets are available in 10 KVA & 20 KVA.
  • Portable Generators in Ratings from 0.5 KVA to 5 KVA Petrol, Kerosene, Diesel driven are also available in popular brands like Honda, Greaves etc.



Diesel Gensets - Water-Cooled - 3.5 kVA To 10 kVA

Diesel Gensets - Water-Cooled - 3.5 kVA To 10 kVA

Diesel Gensets - Water-Cooled - 3.5 kVA to 10 kVA [1 & 3 Phase]
Technical Data ( Standard Gensets)
Petter Type, Water-Cooled Diesel Gensets (Direct Coupled)
1-Phase, 240 Volts, 1500 RPM, 50 Hz, 4 Poles & 1.0 Unity Power Factor
Sr. No. Genset Model No. Resistive Type & Inductive Type A.C. Generator Data kVA (kW) (Max.-Amp) &  Model No. R & I Type Diesel Engine Data HP (kW) (No. Of Cyl.) & Model No. Resistive Type Genset Weight with M.S.Base Frame Nett/Gross (kgs) Inductive Type Genset Weight with M.S.Base Frame Nett/Gross (kgs)
1 52AS-R 62AS-R 3.5 (3.5) (14.6) 35KS-R 6.5 (4.8) (One) 52A, 62A 325 / 510 52AS-R, 62AS-R ---
2 83AS1-R 83AS1-I 5.0 (5.0) (20.8) 50KS-R, 50KS-I 10.0 (7.35) (One) 83A 370 / 555 83AS1-R 375 /560 83AS1-I
3 83AS-R 83AS-I 6.0 (6.0) (25.0) 60KS-R, 60KS-I 10.0 (7.35) (One) 83A 375 /560 83AS-R 380 / 565 83AS-I
4 84AS-R 84AS-I 7.5 (7.5) (31.3) 75KS-R, 75KS-I 12.5 (9.2) (One) 84A 390 / 575 84AS-R 395 / 580 84AS-I
5 89AS-R 89AS-I 7.5 (7.5) (31.3) 75KS-R, 75KS-I 15.0 (11.0) (One) 89A 395 / 580 89AS-R 400 / 585 89AS-I
3-Phase, 415 Volts, 50 Hz, 4 Poles & 0.8 Power Factor (Lagging)
6 69AT-R 70AT-R 5.0 (4.0) (7.0) 50KT-R 7.5 (5.5) (One) 69A, 70A 335 / 520 (69AT-R) 345 / 530 (70AT-R) ---
7 83AT1-R 83AT1-I 6.5 (5.2) (9.0) 65KT-R, 65KT-I 10.0 (7.35) (One) 83A 380 / 565 83AT1-R 365 / 550 83AT1-I
8 83AT-R 83AT-I 7.5 (6.0) (10.4) 75KT-R, 75KT-I 10.0 (7.35) (One) 83A 390 / 575 83AT-R 375 / 560 83AT-I
9 84AT1-R 84AT1-I 8.7 (7.0) (12.2) 87KT-R, 87KT-I 12.5 (9.2) (One) 84A 400 / 585 84AT-R 385 / 570 84AT1-I
10 84AT-R 84AT-I 10.0 (8.0) (13.9) 100KT-R, 100KT-I 12.5 (9.2) (One) 84A 405 / 590 84AT1-R 390 / 575 84AT-I
11 89AT-R 89AT-I 10.0 (8.0) (13.9) 100KT-R, 100KT-I 15.0 (11.0) (One) 89A 410 / 595 89AT-R 390 / 580 89AT-I
Note:
All Above Diesel Engines Computerised With Gensets Are Having Governing Class A2 & Radiator Cooling Arrangement.



Diesel Gensets - Water-Cooled - 10 kVA To 20 kVA

Diesel Gensets - Water-Cooled - 10 kVA To 20 kVA

Diesel Gensets - Water-Cooled - 10 kVA to 20 kVA [1 & 3 Phase]
Technical Data ( Standard Gensets)
Petter Type, Water-Cooled Diesel Gensets (Direct Coupled)
1-Phase, 240 Volts, 1500 RPM, 50 Hz, 4 Poles & 1.0 Unity Power Factor
Sr. No. Genset Model No. Resistive Type & Inductive Type A.C. Generator Data kVA (kW) (Max.-Amp) &  Model No. R & I Type Diesel Engine Data HP (kW) (No. Of Cyl.) & Model No. Resistive Type Genset Weight with M.S.Base Frame Nett/Gross (kgs) Inductive Type Genset Weight with M.S.Base Frame Nett/Gross (kgs)
1 36AS1-R, 86AS1-R 36AS1-I, 86AS1-I 10.0 (10.0) (41.7) 100KS-R, 100KS-I 20.0 (14.7) (Two) 36A, 86A 560/ 780 36AS1-R, 86AS1-R 530 / 750 36AS1-I, 86AS1-I
2 36AS-R, 86AS-R 36AS-I, 86AS-I 12.5 (12.5) (52.1) 125KS-R, 125KS-I 20.0 (14.7) (Two) 36A, 86A 570/ 790 36AS-R, 86AS-R 560 / 780 36AS-I, 86AS-I
3 38AS-R, 87AS-R 38AS-I, 87AS-I 15.0 (15.0) (62.5) 150KS-R, 150KS-I 25.0 (18.4) (Two) 38A, 87A 580/ 800 38AS-R, 87AS-R 585 / 805 38AS-I, 87AS-I
3-Phase, 415 Volts, 50 Hz, 4 Poles & 0.8 Power Factor (Lagging)
4 36AT1-R, 86AT1-R 36AT1-I, 86AT1-I 12.5 (10.0) (17.4) 125KT-R, 125KT-I 20.0 (14.7) (Two) 36A, 86A 580/ 800 36AT1-R, 86AT1-R 520 / 740 36AT1-I, 86AT1-I
5 36AT-R, 86AT-R 36AT-I, 86AT-I 15.0 (12.0) (20.9) 150KT-R, 150KT-I 20.0 (14.7) (Two) 36A, 86A 585/ 805 36AT-R, 86AT-R 545 / 765 36AT-I, 87A6-I
6 38AT1-R, 87AT1-R 38AT1-I, 87AT1-I 17.5 (14.0) (24.3) 175KT-R, 175KT-I 25.0 (18.4) (Two) 38A, 87A 595/ 815 38AT1-R, 87AT1-R 555 / 775 38AT1-I, 87AT1-I
7 38AT-R, 87AT-R 38AT-I, 87AT-I 20.0 (16.0) (27.8) 200KT-R, 200KT-I 25.0 (18.4) (Two) 38A, 87A 615 / 835 38AT-R, 87AT-R 565 / 785 38AT-I, 87AT-I

Note:
All above diesel engines computerised with gensets are having governing class a2 & radiator cooling arrangement.



Diesel Gensets - Water-Cooled - 17.5 kVA to 35 kVA

Diesel Gensets - Water-Cooled - 17.5 kVA to 35 kVA

Diesel Gensets - Water-Cooled - 17.5 kVA to 35 kVA [1 & 3 Phase]
Technical Data ( Standard Gensets)
Petter Type, Water-Cooled Diesel Gensets (Direct Coupled)
1-Phase, 240 Volts, 1500 RPM, 50 Hz, 4 Poles & 1.0 Unity Power Factor
Sr. No. Genset Model No. Resistive Type & Inductive Type A.C. Generator Data kVA (kW) (Max.-Amp) &  Model No. R & I Type Diesel Engine Data HP (kW) (No. Of Cyl.) & Model No. Resistive Type Genset Weight with M.S.Base Frame Nett/Gross (kgs) Inductive Type Genset Weight with M.S.Base Frame Nett/Gross (kgs)
1 300AWBS1-I 300AWS1-I 17.5 (17.5) (72.9) 175KS-I 30.0 (22.0) (Three) 300AWB, 300AW --- 710 / 1070 300AWBS1-I, 300AWS1-I
2 300AWBS-I 300AWS-I 20.0 (20.0) (83.3) 200KS-I 30.0 (22.0) (Three) 300AWB, 300AW --- 800 / 1080 300AWBS-I, 300AWS-I
3 375AWBS1-I 375AWS1-I 22.5 (22.5) (93.8) 225KS-I 37.5 (27.6) (Three) 375AWB, 375AW --- 830 / 1110 375AWBS1-I, 375AWS1-I
4 375AWBS-I 375AWS-I 25.0 (25.0) (104.2) 250KS-I 37.5 (27.6) (Three) 375AWB, 375AW --- 850 / 1130 375AWBS-I, 375AWS-I
5 450AWBS-I 450AWS-I 27.5 (27.5) (114.6) 275KS-I 45.0 (33.0) (Three) 450AWB, 450AW --- 870 / 1150 450AWBS-I, 450AWS-I
3-Phase, 415 Volts, 50 Hz, 4 Poles & 0.8 Power Factor (Lagging)
6 300AWBT1-I 300AWT1-I 22.5 (18.0) (31.3) 225KT-I 30.0 (22.0) (Three) 300AWB, 300AW --- 775 / 1055 300AWBT1-I, 300AWT1-I
7 300AWBT-I 300AWT-I 25.0 (20.0) (34.8) 250KT-I 30.0 (22.0) (Three) 300AWB, 300AW --- 785 / 1065 300AWBT-I, 300AWT-I
8 375AWBT1-I 375AWT1-I 27.5 (22.0) (38.3) 275KT-I 37.5 (27.6) (Three) 375AWB, 375AW --- 800 / 1080 375AWBT1-I, 375AWT1-I
9 375AWBT-I 375AWT-I 30.0 (24.0) (41.7) 300KT-I 37.5 (27.6) (Three) 375AWB, 375AW --- 810 / 1090 375AWBT-I, 375AWT-I
10 450AWBT1-I 450AWT1-I 32.5 (26.0) (45.2) 325KT-I 45.0 (33.0) (Three) 450AWB, 450AW --- 820 / 1100 450AWBT1-I, 450AWT1-I
11 450AWBT-I 450AWT-I 35.0 (28.0) (48.7) 350KT-I 45.0 (33.0) (Three) 450AWB, 450AW --- 830 / 1110 450AWBT-I, 450AWT-I
Note:
All above diesel engines computerized with gen sets are having governing class A2 & radiator cooling arrangement.



Diesel Gensets - Air-Cooled (FTA) - 3.5 kVA To 7.5 kVA

Diesel Gensets - Air-Cooled (FTA) - 3.5 kVA To 7.5 kVA

Diesel Gensets - Air-Cooled (FTA) - 3.5 kVA to 7.5 kVA [1 & 3 Phase]
TECHNICAL DATA ( STANDARD GENSETS)
Petter Type, Air-Cooled (FTA & BTA) Diesel Gensets (Direct Coupled)
1-Phase, 240 Volts, 1500 RPM, 50 Hz, 4 Poles & 1.0 Unity Power Factor
Sr. No. Genset Model No. Resistive Type & Inductive Type A.C. Generator Data kVA (kW) (Max.-Amp) &  Model No. R & I Type Diesel Engine Data HP (kW) (No. Of Cyl.) & Model No. F & B Type Resistive Type Genset Weight with M.S.Base Frame Nett/Gross (kgs) Inductive Type Genset Weight with M.S.Base Frame Nett/Gross (kgs)
1 76AS-RF 77AS-RF 3.5 (3.5) (14.6) 35KS-R 7.5 (5.5) (One) 76A-FTA, 77A-FTA 270 / 420 (76AS-RF) 285 / 435 (77AS-RF) ---
2 85AS1-RF 85AS1-IF 5.0 (5.0) (20.8) 50KS-R, 50KS-I 10.0 (7.35) (One) 85A-FTA 325 / 475 85AS1-RF 330 / 480 85AS1-IF
3 85AS-RF 85AS-IF 6.0 (6.0) (25.0) 60KS-R, 60KS-I 10.0 (7.35) (One) 85A-FTA 335 / 485 85AS-RF 340 / 490 85AS-IF
3-Phase, 415 Volts, 50 Hz, 4 Poles & 0.8 Power Factor (Lagging)
4 57AT-RF 67AT-RF 5.0 (4.0) (7.0) 50KT-R 8.0 (5.9) (One) 57A-FTA, 67A-FTA 305 / 455 (57AT-RF) 320 / 470 (67AT-RF) ---
5 85AT1-RF 85AT1-IF 6.5 (5.2) (9.0) 65KT-R, 65KT-I 10.0 (7.35) (One) 85A-FTA 340 / 490 85AT1-RF 325 / 475 85AT1-IF
6 85AT-RF 85AT-IF 7.5 (6.0) (10.4) 75KT-R, 75KT-I 10.0 (7.35) (One) 85A-FTA 345 / 495 85AT-RF 330 / 480 85AT-IF

Note:
All Above Diesel Engines Comprised With Gensets Are Having Governing Class A2.
  • FTA = Fan Type Air-Cooled
  • BTA = Blower Type Air-Cooled
Resistive (Load) Type A.C.Generators are made of m.s. body & are double ball bearing type. These are self excited, drip prrof, screen protected & self ventilated. class of winding is 'f' & are diode type. The degree of protection is IP21. Voltage regulation is +/- 10%. resistive (Load) type diesel gensets are suitable for light duty / low torque load applications such as lightening, electric fans & other light duty domestic loads etc.

Inductive (Load) Type A.C.Generators are made of aluminium body & are double ball bearing type. these are self excited, drip proof, screen protected & self ventilated. class of winding is 'h' & are transformer type. The degree of protection is IP23. Voltage regulation is +/- 5%. Brushless with avr (automatic voltage regulator) type a.c. generators instead of transformer type a.c. generators can also be made available with voltage regulation +/- 1%. Inductive (Load) type diesel gensets are suitable for heavy duty / high torque load applications such as for running electric motors, submersible pumpsets, air-conditioners etc.

For any type of long duration high torque load, technically different specification & site conditions, diesel genset has to be selected accordingly. For such application kindly contact us for right selection.



Diesel Gensets - Air-Cooled (BTA) - 3.5 kVA To 7.5 kVA

Diesel Gensets - Air-Cooled (BTA) - 3.5 kVA To 7.5 kVA

Diesel Gensets - Air-Cooled (BTA) - 3.5 kVA to 7.5 kVA [1 & 3 Phase], also known as air cooled diesel gensets.
Technical Data ( Standard Gensets)
Petter Type, Air-Cooled (FTA & BTA) Diesel Gensets (Direct Coupled)
1-Phase, 240 Volts, 1500 RPM, 50 Hz, 4 Poles & 1.0 Unity Power Factor
Sr. No. Genset Model No. Resistive Type & Inductive Type A.C. Generator Data kVA (kW) (Max.-Amp) &  Model No. R & I Type Diesel Engine Data HP (kW) (No. Of Cyl.) & Model No. F & B Type Resistive Type Genset Weight with M.S.Base Frame Nett/Gross (kgs) Inductive Type Genset Weight with M.S.Base Frame Nett/Gross (kgs)
1 76AS-RB 77AS-RB 3.5 (3.5) (14.6) 35KS-R 7.5 (5.5) (One) 76A-BTA, 77A-BTA 285 / 435 (76AS-RB) 290 / 440 (77AS-RB) ---
2 85AS1-RB 85AS1-IB 5.0 (5.0) (20.8) 50KS-R, 50KS-I 10.0 (7.35) (One) 85A-BTA 330 / 480 85AS1-RB 335 / 485 85AS1-IB
3 85AS-RB 85AS-IB 6.0 (6.0) (25.0) 60KS-R, 60KS-I 10.0 (7.35) (One) 85A-BTA 340 / 490 85AS-RB 345 / 495 85AS-IB
3-Phase, 415 Volts, 50 Hz, 4 Poles & 0.8 Power Factor (Lagging)
4 57AT-RB 67AT-RB 5.0 (4.0) (7.0) 50KT-R 8.0 (5.9) (One) 57A-BTA, 67A-BTA 325 / 475 57AT-RB, 67AT-RB ---
5 85AT1-RB 85AT1-IB 6.5 (5.2) (9.0) 65KT-R, 65KT-I 10.0 (7.35) (One) 85A-BTA 345 / 495 85AT1-RB 330 / 480 85AT1-IB
6 85AT-RB 85AT-IB 7.5 (6.0) (10.4) 75KT-R, 75KT-I 10.0 (7.35) (One) 85A-BTA 350 / 500 85AT-RB 335 / 485 85AT-IB
Note:

All Above Diesel Engines Comprised With Gensets Are Having Governing Class A2.
  • FTA = Fan Type Air-Cooled
  • BTA = Blower Type Air-Cooled
Resistive (Load) Type A.C.Generators are made of m.s. body & are double ball bearing type. These are self excited, drip prrof, screen protected & self ventilated. Class of winding is 'F' & are diode type. The degree of protection is IP21. Voltage regulation is +/- 10% resistive (Load) type diesel gensets are suitable for light duty / low torque load applications such as lightening, electric fans & other light duty domestic loads etc.

Inductive (Load) Type A.C.Generators are made of aluminium body & are double ball bearing type. these are self excited, drip proof, screen protected & self ventilated. Class of winding is 'H' & are transformer type. The degree of protection is IP23. Voltage regulation is +/- 5% brushless with AVR (Automatic Voltage Regulator) Type A.C. Generators instead of transformer type A.C. generators can also be made available with voltage regulation +/- 1%. Inductive (Load) type diesel gensets are suitable for heavy duty and high torque load applications such as for running electric motors, submersible pumpsets, air-conditioners etc.

For any type of long duration high torque load, technically different specification & site conditions, diesel genset has to be selected accordingly. For such application kindly contact us for right selection.



Diesel Gensets Air Cooled

Diesel Gensets Air Cooled

Technical Data ( Standard Gensets)
Petter Type, Air-Cooled (FTA & BTA) Diesel Gensets (Direct Coupled)
1-Phase, 240 Volts, 1500 RPM, 50 Hz, 4 Poles & 1.0 Unity Power Factor
Sr. No. Genset Model No. Resistive Type & Inductive Type A.C. Generator Data kVA (kW) (Max.-Amp) & Model No. R & I Type Diesel Engine Data HP (kW) (No. Of Cyl.) & Model No. F & B Type Resistive Type Genset Weight with M.S.Base Frame Nett/Gross (kgs) Inductive Type Genset Weight with M.S.Base Frame Nett/Gross (kgs)
1 41AS-RF, 80AS-RF 41AS-IF, 80AS-IF 7.5 (7.5) (31.3) 75KS-R, 75KS-I 15.0 (11.0) (Two) 41A-FTA, 80A-FTA 440 / 615 41AS-RF, 80AS-RF 445 / 620 41AS-IF, 80AS-IF
2 44AS1-RF, 88AS1-RF 44AS1-IF, 88AS1-IF 10.0 (10.0) (41.7) 100KS-R, 100KS-I 20.0 (14.7) (Two) 44A-FTA, 88A-FTA 510 / 685 44AS1-RF, 88AS1-RF 485 / 660 44AS1-IF, 88AS1-IF
3 44AS-RF, 88AS-RF 44AS-IF, 88AS-IF 12.5 (12.5) (52.1) 125KS-R, 125KS-I 20.0 (14.7) (Two) 44A-FTA, 88A-FTA 515 / 690 44AS-RF, 88AS-RF 510 / 685 44AS-IF, 88AS-IF
3-Phase, 415 Volts, 50 Hz, 4 Poles & 0.8 Power Factor (Lagging)
4 41AT-RF, 80AT-RF 41AT-IF, 80AT-IF 8.7 (7.0) (12.2) 87KT-R, 87KT-I 15.0 (11.0) (Two) 41A-FTA, 80A-FTA 455 / 630 41AT-RF, 80AT-RF 435 / 610 41AT-IF, 80AT-IF
5 42AT-RF, 81AT-RF 42AT-IF, 81AT-IF 10.0 (8.0) (13.9) 100KT-R, 100KT-I 16.0 (11.8) (Two) 42A-FTA, 81A-FTA 465 / 640 42AT-RF, 81AT-RF 445 / 620 42AT-IF, 81AT-IF
6 44AT1-RF, 88AT1-RF 44AT1-IF, 88AT1-IF 12.5 (10.0) (17.4) 125KT-R, 125KT-I 20.0 (14.7) (Two) 44A-FTA, 88A-FTA 535 / 710 44AT1-RF, 88AT1-RF 470 / 645 44AT1-IF, 88AT1-IF
7 44AT-RF, 88AT-RF 44AT-IF, 88ATI-IF 15.0 (12.0) (20.9) 150KT-R, 150KT-I 20.0 (14.7) (Two) 44A-FTA, 88A-FTA 540 / 715 44AT-RF, 88AT-RF 500 / 675 44AT-IF, 88AT-IF





Diesel Gensets-Air-Cooled (BTA)-7.5 kVA to 15 kVA-1500 RPM

Diesel Gensets-Air-Cooled (BTA)-7.5 kVA to 15 kVA-1500 RPM

Technical Data ( Standard Gensets)
Petter Type, Air-Cooled (FTA & BTA) Diesel Gensets (Direct Coupled)
1-Phase, 240 Volts, 1500 RPM, 50 Hz, 4 Poles & 1.0 Unity Power Factor
Sr. No. Genset Model No. Resistive Type & Inductive Type A.C. Generator Data kVA (kW) (Max.-Amp) &  Model No. R & I Type Diesel Engine Data HP (kW) (No. Of Cyl.) & Model No. F & B Type Resistive Type Genset Weight with M.S.Base Frame Nett/Gross (kgs) Inductive Type Genset Weight with M.S.Base Frame Nett/Gross (kgs)
1 41AS-RB, 80AS-RB 41AS-IB, 80AS-IB 7.5 (7.5) (31.3) 75KS-R, 75KS-I 15.0 (11.0) (Two) 41A-BTA, 80A-BTA 450 / 625 41AS-RB, 80AS-RB 455 / 630 41AS-IB, 80AS-IB
2 44AS1-RB, 88AS1-RB 44AS1-IB, 88AS1-IB 10.0 (10.0) (41.7) 100KS-R, 100KS-I 20.0 (14.7) (Two) 44A-BTA, 88A-BTA 520 / 695 44AS1-RB, 88AS1-RB 495 / 670 44AS1-IB, 88AS1-IB
3 44AS-RB, 88AS-RB 44AS-IB, 88AS-IB 12.5 (12.5) (52.1) 125KS-R, 125KS-I 20.0 (14.7) (Two) 44A-BTA, 88A-BTA 525 / 700 44AS-RB, 88AS-RB 520 / 695 44AS-IB, 88AS-IB
3-Phase, 415 Volts, 50 Hz, 4 Poles & 0.8 Power Factor (Lagging)
4 41AT-RB, 80AT-RB 41AT-IB, 80AT-IB 8.7 (7.0) (12.2) 87KT-R, 87KT-I 15.0 (11.0) (Two) 41A-BTA, 80A-BTA 465 / 640 41AT-RB, 80AT-RB 445 / 620 41AT-IB, 80AT-IB
5 42AT-RB, 81AT-RB 42AT-IB, 81AT-IB 10.0 (8.0) (13.9) 100KT-R, 100KT-I 16.0 (11.8) (Two) 42A-BTA, 81A-BTA 475 / 650 42AT-RB, 81AT-RB 455 / 630 42AT-IB, 81AT-IB
6 44AT1-RB, 88AT1-RB 44AT1-IB, 88AT1-IB 12.5 (10.0) (17.4) 125KT-R, 125KT-I 20.0 (14.7) (Two) 44A-BTA, 88A-BTA 545 / 720 44AT1-RB, 88AT1-RB 480 / 655 44AT1-IB, 88AT1-IB
7 44AT-RB, 88AT-RB 44AT-IB, 88ATI-IB 15.0 (12.0) (20.9) 150KT-R, 150KT-I 20.0 (14.7) (Two) 44A-BTA, 88A-BTA 550 / 725 44AT-RB, 88AT-RB 510 / 685 44AT-IB, 88AT-IB
Note:
All above diesel engines comprised with gensets are having governing class a2. * FTA = fan type air-cooled * BTA = blower type air-cooled

Resistive (Load) Type A.C.Generators are made of m.s. body & are double ball bearing type. these are self excited, drip prrof, screen protected & self ventilated. Class of winding is 'F' & Are Diode Type. The Degree of Protection is IP21. Voltage regulation is +/- 10% resistive (Load) type diesel gensets are suitable for light duty / low torque load applications such as lightening, electric fans & other light duty domestic loads etc.




Contact Us

Industrial Machinery Agency
Mr. Sanjay Shah (Manager)
22-D, S. A. Brelvi Road, 112, Wadia Building, Near Mumbai Samachar Press, Fort
Mumbai - 400001, Maharashtra, India


Home  |  About Us  |  Our Products  |  Trade Offers (17)   |   Site Map  |   Contact Us   |   Mobile Site

© Industrial Machinery Agency. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited